EasyManuals Logo

Kollmorgen AKD Basic User Manual

Kollmorgen AKD Basic
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #463 background imageLoading...
Page #463 background image
AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.33.11 VL.FBFILTER
General Information
Type R/O Parameter
Description
Filters VL.FB value; active in opmodes 1 (velocity) and 2 (position)
only.
Units
Depends on UNIT.VROTARY or UNIT.VLINEAR
Rotary: rpm, rps, deg/s, (custom units)/s, rad/s
Linear: counts/s, mm/s, µm/s, (custom units)/s
Range N/A
Default
Value
N/A
Data Type Float
See Also VL.FB
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
EtherCAT COE and CAN-
open
3407h/1 M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 858 Yes low 32 bit word Yes M_01-03-00-000
Description
This parameter returns the same value as VL.FB , filtered through a 10 Hz filter.
463 Kollmorgenâ„¢ | March 30, 2012

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD Basic and is the answer not in the manual?

Kollmorgen AKD Basic Specifications

General IconGeneral
BrandKollmorgen
ModelAKD Basic
CategoryController
LanguageEnglish

Related product manuals