AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.32.5 VBUS.UVMODE
General Information
Type N/V Parameter
Description
Indicates undervoltage (UV)
mode.
Units N/A
Range 0 to 1
Default
Value
1
Data Type Integer
See Also N/A
Start Version M_01-00-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 802 No 8 bit No M_01-03-00-000
Description
This parameter indicates undervoltage (UV) mode.
When VBUS.UVMODE - 0, an undervoltage fault is issued whenever the DC bus goes below
the undervoltage threshold.
When VBUS.UVMODE = 1, an undervoltage fault is issued whenever the DC bus goes below
the
under voltage threshold and the controller attempts to enable the drive (software or hardware
enable).
445 Kollmorgenâ„¢ | March 30, 2012