AKD BASIC User Guide | 6 AKD BASIC Parameters, Operators, Statements
6.16.1 FB2.ENCRES
General Information
Type NV Parameter
Description
Sets the secondary feedback (FB2) res-
olution.
Units counts/rev
Range 0 to 262,140 counts/rev
Default
Value
0
Data Type Integer
See Also FB2.MODE, FB2.SOURCE
Start Version M_01-03-00-000
Fieldbus Index/Subindex Is 64 bit? Attributes Signed?
Modbus 984 No 32 bit No
Description
This parameter sets the feedback 2 (FB2) resolution and defines how many counts input into
the secondary feedback will be considered a full revolution.
291 Kollmorgenâ„¢ | March 30, 2012