4 Playback
4.2 Playback
4-12
149235-1CD
RE-CSO-A031
Check Mode Operation
The machine runs without issuing work instructions, such as the ARCON instruction. It is used
primarily to check the path of the program.
Weaving Prohibit Setting during Check Mode Operation
The weaving operation is not executed in the weaving section of the job.
Cancel All Special Operations
All special operations are disabled by the following operation
Operation Explanation
1 Select “CHECK-RUN” under
the SPECIAL PLAY window.
The setting alternates between “VALID” and “INVALID.”
2 Select “COMPLETE.” The window returns to the PLAYBACK window.
Operation Explanation
1 Select “WEAV PROHIBIT IN
CHK-RUN” under the
SPECIAL PLAY window.
The setting alternates between “VALID” and “INVALID.”
2 Select “COMPLETE.” The window returns to the PLAYBACK window.
Operation Explanation
1 Select {EDIT} from the menu.
2 Select “CANCEL ALL
SELECT.”
The message “All special functions canceled” appears.
Special operations are also automatically cancelled if the main power is shut OFF.
NOTE
164 of 493

Table of Contents

Other manuals for YASKAWA NX100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA NX100 and is the answer not in the manual?

YASKAWA NX100 Specifications

General IconGeneral
ManufacturerYASKAWA
ModelNX100
Operating Temperature0 to 45°C
Humidity20 to 80% RH (non-condensing)
Communication InterfacesEthernet
Safety StandardsISO 10218-1
Power Supply200-230V AC, 50/60Hz