9 Arc Welding Application
9.5 Welding Condition Files
9-58
149235-1CD
RE-CSO-A031
Editing the Arc End Condition File
Editing COMMENT
Editing ANTI-STICK
Editing Other Items
9.5.9 Welding Speed Specifications
The welding speed is determined by one of the following:
• Welding speed specified by play speed of the move instruction
• Welding speed specified by the ARCON instruction or arc start condition file
When the move instruction does not specify a speed
Welding is performed at the ARCON instruction or arc start condition file speed.
When the move instruction and ARCON instruction specify different speeds
Priority is given to one according to the parameter values described below. To switch the priorities,
change the parameter setting.
Operation Explanation
1 Select “COMM.”
2 Input characters.
Operation Explanation
1 Select “ANTI-STICK.” Each time [SELECT] is pressed, the indication alternates
between “ON” and “OFF.”
Operation Explanation
1 Select an item to be edited.
2 Input the number using the
Numeric keys.
Parameter Contents Initial Value
AxP005
x: Application number
Move instruction speed is priority : 0
ARCON instruction speed is priority : 1
0
401 of 493

Table of Contents

Other manuals for YASKAWA NX100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA NX100 and is the answer not in the manual?

YASKAWA NX100 Specifications

General IconGeneral
ManufacturerYASKAWA
ModelNX100
Operating Temperature0 to 45°C
Humidity20 to 80% RH (non-condensing)
Communication InterfacesEthernet
Safety StandardsISO 10218-1
Power Supply200-230V AC, 50/60Hz
Storage Temperature60°C

Related product manuals