8 Parameter
8.3 Mode Operation Setting Parameters
8-11
149235-1CD
RE-CSO-A031
8.3 Mode Operation Setting Parameters
These parameters set various operations in the teach mode or remote mode.
S2C147: SECURITY MODE WHEN CONTROL POWER SUPPLY
IS TURNED ON
The operation level when the control power supply is turned ON is set.
S2C148: SELECTION OF CARTESIAN/CYLINDRICAL
This parameter specifies whether the cartesian mode or cylindrical mode is affected when cartesian/
cylindrical mode is selected by operation (coordinate) mode selection at axis operation of programming
pendant. This specification can be done on the TEACHING CONDITION window.
S2C149: COORDINATE SWITCHING PROHIBITED
This parameter prohibits switching coordinates during JOG operation by the programming pendant.
0: Operation Mode
1: Editing Mode
2: Management Mode
0: Cylindrical mode
1: Cartesian mode
0: Switching permitted for tool coordinates and user coordinates
1: Switching prohibited for tool coordinates
2: Switching prohibited for user coordinates
3: Switching prohibited for tool coordinates and user coordinates
300 of 493

Table of Contents

Other manuals for YASKAWA NX100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA NX100 and is the answer not in the manual?

YASKAWA NX100 Specifications

General IconGeneral
ManufacturerYASKAWA
ModelNX100
Operating Temperature0 to 45°C
Humidity20 to 80% RH (non-condensing)
Communication InterfacesEthernet
Safety StandardsISO 10218-1
Power Supply200-230V AC, 50/60Hz
Storage Temperature60°C

Related product manuals