7 External Memory Devices
7.2 Handling Data
7-8
149235-1CD
RE-CSO-A031
7.2.2 Collective Backup
For the NX100, four types of collective backup are available: CMOS.BIN, CMOSBK.BIN,
ALCMSxx.HEX, and CMOSxx.HEX.
CMOS.BIN
For the normal backup, use this data.
Save: Perform in the maintenance mode (the editing mode or higher.)
Load: Perform in the maintenance mode (the management mode.)
As for the load/save procedures, refer to “NX100 INSTRUCTIONS”.
Target Area: All areas of the internally-stored data. (Note that the monitoring time is not loaded.)
CMOSBK.BIN
This data is used in the automatic backup function.
Save: In the normal mode, saves with the preset conditions.
Load: Perform for the system restoration in the maintenance mode (the management mode.)
For details, refer to “NX100 INSTRUCTIONS”.
Target Area: All areas of the internally-stored data. (Note that the monitoring time is not loaded.)
CMOSxx.HEX
This data is loaded/saved in the FD/CF menu of the normal mode.
Save: Perform in the normal mode (the editing mode or higher.)
Load: Perform in the normal mode (the management mode.)
For details, refer to the following pages.
Target Area: The collected data including "Job File", "Data File", "Parameter File", "System
Data", and "I/O Data" which can be individually loaded/saved in the FD/CF menu. Because
the setting information of robot etc. are not included in the collected data, the system cannot
be completely restored.
ALCMSxx.HEX
This data is for the manufacturer only. Users can save but cannot load this data.
In order to save the batch data, the following free space per file is needed in the Compact Flash card.
JZNC-NIF01-1: (The number of stored file + 1) x 7.5 MByte
JZNC-NIF01-2: (The number of stored file + 1) x 11.0 MByte
Note that the free space for one working file is needed in addition to the above mentioned space when
using the automatic backup function.
Besides, it is recommended to store the backup data in two or more Compact Flash cards to minimize
problems if the Compact Flash card is damaged.
252 of 493

Table of Contents

Other manuals for YASKAWA NX100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA NX100 and is the answer not in the manual?

YASKAWA NX100 Specifications

General IconGeneral
ManufacturerYASKAWA
ModelNX100
Operating Temperature0 to 45°C
Humidity20 to 80% RH (non-condensing)
Communication InterfacesEthernet
Safety StandardsISO 10218-1
Power Supply200-230V AC, 50/60Hz
Storage Temperature60°C

Related product manuals