8 Parameter
8.7 Parameters for Other Functions or Applications
8-46
149235-1CD
RE-CSO-A031
S2C332: RELATIVE JOB OPERATION METHOD
This parameter specifies how to operate a relative job. A method to convert a relative job into a
standard job (pulse), and a conversion method to calculate the aimed position (pulse position) when a
relative job is operated can be specified.
S3C819 to S3C898: ANALOG OUTPUT FILTER CONSTANT
(When analog output corresponding to speed function is used)
By setting a constant to filter, a filter processing can be performed for the output analog signal.
S3C899: CUT WIDTH CORRECTION VALUE (When form cutting
function is used)
This parameter specifies the path correction value for pattern cutting operation. A value 1/2 of the cut
width is set in units of μm.
0: Previous step with priority (B-axis moving distance minimized.)
1: Form with priority
2 Previous step with priority (R-axis moving distance minimized.)