9 Arc Welding Application
9.4 Registering Arc Welding Instructions
9-14
149235-1CD
RE-CSO-A031
Setting Welding Start Conditions
The ARCON instruction can be registered in any of the following three ways:
• With additional items to specify conditions
ARCON AC=200 AVP=100 T=0.50 V=60 RETRY
• With an arc start condition file
ARCON ASF# (1)
In this case, the welding condition is set using the arc start condition file. (Refer to section
9.5 "Welding Condition Files")
• Without additional items
ARCON
In this case, the welding condition must be set using the welding condition set instruction
(ARCSET) before the ARCON instruction is executed. (Refer to section 9.4.3
"ARCSET".”)
With Additional Items to Specify Conditions
Operation Explanation
1 Select the ARCON instruction
in the instruction area.
The ARCON instruction appears in the input buffer line.
2 Press [SELECT]. The DETAIL EDIT window appears. Select “UNUSED.”
JOB
EDIT
DISPLAY
UTILITY
Main Menu ShortCut
! Turn on servo power
JOB CONTENT
JOB NAME: WORK A
0000 NOP
0001 MOVJ VJ=80.00
0002 MOVL V=800
0003 END
ARCON
TOOL: 00
CONTROL GROUP: R1
STEP NO: 0003
DETAIL EDIT
ARCON
ARCON
SET METHOD
: UNUSED
DATA
EDIT
DISPLAY
UTILITY
Main Menu ShortCut
! Turn on servo power