8 Parameter
8.5 Parameters according to Status I/O
8-34
149235-1CD
RE-CSO-A031
8.5 Parameters according to Status I/O
These parameters set the parity check or I/O setting for user input/output signals.
S2C187: USER OUTPUT RELAY WHEN CONTROL POWER IS
ON
This parameter specifies the state of the user output relays when the control power is turned ON. Since
the power OFF state, including peripheral devices, cannot be completely reproduced, take note when
restarting.
0: Reset to the power OFF state
1: Initialized (all user relays OFF)
323 of 493

Table of Contents

Other manuals for YASKAWA NX100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA NX100 and is the answer not in the manual?

YASKAWA NX100 Specifications

General IconGeneral
ManufacturerYASKAWA
ModelNX100
Operating Temperature0 to 45°C
Humidity20 to 80% RH (non-condensing)
Communication InterfacesEthernet
Safety StandardsISO 10218-1
Power Supply200-230V AC, 50/60Hz
Storage Temperature60°C

Related product manuals