8 Parameter
8.3 Mode Operation Setting Parameters
8-17
149235-1CD
RE-CSO-A031
S2C174: RESERVED START
This parameter specifies whether a reserved start instruction from the programming pendant is
accepted or not. The specification can be done on the OPERATING CONDITION window.
S2C176: JOB SELECTION AT REMOTE FUNCTION (PLAY
MODE)
This parameter specifies whether a job selection in play mode at remote function is prohibited or not.
S2C177: EXTERNAL MODE SWITCH
This parameter specifies whether mode switching from the outside is accepted or not. The
specification can be done on the OPERATING CONDITION window.
S2C179: EXTERNAL CYCLE SWITCHING
This parameter specifies whether cycle switching from the outside is accepted or not. The specification
can be done on the OPERATING CONDITION window.
S2C180: PROGRAMMING PENDANT CYCLE SWITCHING
This parameter specifies whether cycle switching from the programming pendant is accepted or not.
The specification can be done on the OPERATING CONDITION window.
S2C181: SERVO ON FROM EXTERNAL PP PROHIBITION
This parameter specifies whether a servo ON instruction is accepted or not. More than one instruction
can be specified. For example, to permit the servo ON instruction from an external input only, set “6.”
In this case, servo ON instruction from the programming pendant is not accepted.The specification can
be done on the OPERATING CONDITION window.
0: Permitted
1: Prohibited
0: Permitted
1: Prohibited
0: Permitted
1: Prohibited
0: Permitted
1: Prohibited
0: Permitted
1: Prohibited
d7 d0
External input prohibited
Programming pendant
: 1 (VA LID )
: 2 (VA LID )
: 4 (VA LID )
DSW