Page #462 background image
10 Table of Basic Instructions
10.2 I/O Instructions
10-7
149235-1CD
RE-CSO-A031
ARATION
Function
Starts the analog output corresponding to the speed.
Additional
Item
AO#(<output port number>) 1 to 40
BV = <basic voltage> -14.00 to 14.00
V = <basic speed> 0.1 to
150.0 mm/s
1 to 9000 cm/
min
OFV = <offset voltage> -14.00 to 14.00
Example
ARATION AO#(1) BV=10.00 V=200.0 OFV=2.00
ARATIOF
Function
Ends the analog output corresponding to the speed.
Additional
Item
AO#(<output port number>) 1 to 40
Example
ARATIOF AO#(1)