Reload the standby switch.
Alternatively, you could ignore the MCL by following these steps:
1
Enter the redundancy config-sync ignore mismatched-commands command.
2
Reload the standby switch; the system transitions to SSO mode.
If you ignore the mismatched commands, the out-of-synchronization configuration on the active switch
and the standby switch still exists.
Note
3
You can verify the ignored MCL with the show redundancy config-sync ignored mcl command.
Each command sets a return code in the action function that implements the command. This return code
indicates whether or not the command successfully executes. The active switch maintains the PRC after
executing a command. The standby switch executes the command and sends the PRC back to the active switch.
A PRC failure occurs if these two PRCs do not match. If a PRC error occurs at the standby switch either
during bulk synchronization or line-by-line (LBL) synchronization, the standby switch is reset. To display all
PRC failures, use the show redundancy config-sync failures prc command.
To display best effort method (BEM) errors, use the show redundancy config-sync failures bem command.
Examples
This example shows how to display the BEM failures:
Device> show redundancy config-sync failures bem
BEM Failed Command List
-----------------------
The list is Empty
This example shows how to display the MCL failures:
Device> show redundancy config-sync failures mcl
Mismatched Command List
-----------------------
The list is Empty
This example shows how to display the PRC failures:
Device# show redundancy config-sync failures prc
PRC Failed Command List
-----------------------
The list is Empty
Command Reference, Cisco IOS XE Everest 16.5.1a (Catalyst 3650 Switches)
870
show redundancy config-sync