December 2004 NEC Business Solutions Ltd
104 – Chapter 1 DRAFT 3 Hold Recall Time Selection (Exclusive), 1-1-63
Doc. No.: 8194 - Release 2.0
December 2004
3
Use the dial pad to enter the time required.
Note:
Jto move cursor left.
Lto move cursor right.
Setting Data (Allow): Class 1 to Class 4: 000 to 999
sec
000 = No
Limit
Default values:
Class 1 to Class 4 = 60 secs
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-03 Hold Recall Timer Selection (Non Exclusive Hold)
1-2-23 System Call Park Recall Time Selection
4-71 Time Class Assignment for Telephone Mode (R2000 and above)
N
When an Exclusive Hold call recalls, the held call switches to a Non-Exclusive Hold call.
Programming Procedures (Continued)