EasyManua.ls Logo

NEC Xen IPK - Minute Alarm Selection

NEC Xen IPK
638 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-94, 3-Minute Alarm Selection DRAFT 3 Chapter 1 – 479
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
4-94
System Mode
4
Submode
Data No.
94
PC Programming
+ BTI
3-Minute Alarm Selection
General Description
Use this Memory Block to specify, per station, whether or not a warning signal tone is generated
at 3-minute intervals during an outgoing or incoming CO/PBX call.
Display
Settings
LK 1LK 2LK 3LK 4
The shaded area indicates
the default setting.
No Ys
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1
Go off-line.
2
Press LK4 +ID to access the Memory Block.
3
Press the corresponding CO/PBX line key to change data option.
Note: Use the following to change option:
R select next Tel Port No.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
N
1. A 1-second (approximately) warning signal sounds every 3 minutes during CO/PBX calls.
2. The alarm tone is heard through the terminal speaker only.
3. If the built-in speakerphone is used for Handsfree, the warning signal is not used.
4. Telephone ports A0~C0 are ports 100~120.
0 1 / 9 4 : 3 m A L M N O
T I M E D I S P L A Y
Data
No.
Tel Port No.
(01~99)
A0~C0
Title
Setting
Data

Table of Contents

Related product manuals