352 ā Chapter 1 DRAFT 3 Tie Line Prepause Time Selection, 3-16
December 2004 NEC Business Solutions Ltd
Doc. No.: 8194 - Release 2.0
December 2004
3-16
System Mode
3
Submode
ā
Data No.
16
PC Programming
+ ALM
Tie Line Prepause Time
Selection
General Description
Use this Memory Block to specify the time (prepause) when the originating side becomes able to
send dial pulse or dual-tone multi-frequency (DTMF) to the distant system.
Display
Settings
(Page 1)
LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
0 sec. 0.5 sec. 1.0 sec. 1.5 sec.
LK 5 LK 6 LK 7 LK 8
2.0 sec. 3.0 sec. 4.0 sec. 5.0 sec.
(Page 2)
LK 1 LK 2 LK 3 LK 4
6.0 sec. 7.0 sec. 8.0 sec. 9.0 sec.
LK 5 LK 6 LK 7 LK 8
10.0 sec. 11.0 sec. 12.0 sec. 13.0 sec.
Programming Procedures
1
Go off-line.
2
Press LK3 + N + AF to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
Note: The following to enter data:
S to go to the next page
T to go to the previous page
R to go to the next CO/PBX Line No.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
N
Prepause time differs according to the acknowledgment signalling method.
0 1 / 1 6 : P R E 0 | 1
T I M E D I S P L A Y
CO/PBX
No.
(01~64)
Data
No.
Title
Setting
Data
Page
No.