1-1-07, Tie Line Delay Ringing Timer Selection DRAFT 3 Chapter 1 – 41
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
1-1-07
System Mode
1
Submode
1
Data No.
07
PC Programming
+ BCM
Tie Line Delay Ringing
Timer Selection
General Description
A Tie line call ringing at a station can begin ringing at other preassigned stations if it is not
answered in a predetermined time. This Memory Block defines the time, and CO/PBX Ringing
Assignment defines the preassigned station.
With IPK R2000 and above, this memory block allows flexible entries and has four classes.
For R2000 only.
For R2000 and above.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
10 sec. 20 sec. 30 sec.
∞
LK 5LK 6LK 7LK 8
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK1 + KG to access the Memory Block.
3
Use the dial pad to enter the time required.
Note:
Jto move cursor left.
Lto move cursor right.
Setting Data (Allow): Class 1 to Class 4: 000 to 255 sec
000 = No Limit
Default values:
Class 1 to Class 4 = 000 secs (unlimited)
4
PressNto write the data.
5
PressPto go back on-line.
0 7 : T L D L Y R N G ∞
T I M E D I S P L A Y
Data
No.
Title
Setting
Data
0 7 : T L D L Y X = 0 0 0 s
T I M E D I S P L A Y
Data
No.
Title
Setting
Data