206 – Chapter 1 DRAFT 3 External Speaker Connection Selection, 1-7-02
December 2004 NEC Business Solutions Ltd
Doc. No.: 8194 - Release 2.0
December 2004
1-7-02
System Mode
1
Submode
7
Data No.
02
PC Programming
+ BP
External Speaker Connection
Selection
General Description
Use this Memory Block to specify whether or not external speakers are connected to the system.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
ESP A ESP B ESP C
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1
Go off-line.
2
Press LK1 + LK7 + KB to access the Memory Block.
3
Press the CO/PBX line key corresponding to each ESP Zone. The LED changes to indicate the data each time the CO/PBX
line key is pressed.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-7-03 External Paging Alert Tone Selection
N
Only three external speaker zones can be connected to the system.
0 2 : E S P C O N N
T I M E D I S P L A Y
Data
No.
Title
CO/PBX
Line LED
Off On
Data No Yes
There is no
default setting.