Loading...
324 – Chapter 1 DRAFT 3 Centralised BLF Send Time Assignment, 1-15-17
December 2004 NEC Business Solutions Ltd
Doc. No.: 8194 - Release 2.0
December 2004
1-15-17
System Mode
1
Submode
15
Data No.
17
PC Programming
+ AW
Centralised BLF Send Time
Assignment
General Description
Use this Memory Block to assign the time interval for sending BLF information across the K-
CCIS Network.
System Software R2000 or higher is required.
Display
Settings
LK1 LK2 LK3 LK4 LK5 LK6 LK7 LK8
The shaded area indicates
the default setting.
4 Seconds
(04s)
4 Seconds
(08s)
4 Seconds
(12s)
4 Seconds
(16s)
Programming Procedures
1
Go off-line.
2
Press LK1 + LK15 + AG to access the Memory Block.
3
Press corresponding CO/PBX line key to change the Setting Data option.
4
PressNto write the data, and display the next Memory Block.
5
Program the next Memory Block or p
ressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
7-1 Card Interface Slot Assignment
7-3-01 MIF (LCR) Assignment
7-3-02 MIF (SMDR) Assignment
1-15-00 K-CCIS Main/Remote Office Selection
1-15-02 Common Signal Channel Assignment
1-15-03 Originating Point Code Assignment
1-15-04 Destination Point Code Assignment
1-15-05 Destination Point Code Transfer Assignment
1-15-06 Originating Office Code Number Assignment
1-15-07 K-CCIS Message Response Timeout Assignment
1-15-08 Link Reconnect Allow/Deny Selection
1-15-09 K-CCIS Maximum Call Forwarding Hop Assignment
1 7 : S E N D T I M E 0 4 s