EasyManua.ls Logo

NEC Xen IPK - Digit Matching Table to Normal Dial Assignment

NEC Xen IPK
638 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-1-66, 8-Digit Matching Table to Normal Dial Assignment DRAFT 3 Chapter 1 – 107
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
1-1-66
System Mode
1
Submode
1
Data No.
66
PC Programming
+ AC
8-Digit Matching Table to
Normal Dial Assignment
General Description
Use this Memory Block to assign the 8-Digit Matching Table by class for normal dialling as used
or unused. If unused is assigned, the system does not check during normal dialling even if
Memory Block 1-1-61 8-Digit Matching Table to Class Assignment is programmed.
Display
Settings
(Page 1) (Page 2)
LK 1 LK 2 LK 3 LK 4 LK 1 LK 2 LK 3 LK 4
There is no
default setting.
Table 00 Table 01 Table 02 Table 03 Table 08 Table 09 Table 10 Table 11
LK 5 LK 6 LK 7 LK 8 LK 5 LK 6 LK 7 LK 8
Table 04 Table 05 Table 06 Table 07 Table 12 Table 13 Table 14 Table 15
Programming Procedures
1
Go off-line.
2
Press LK1 + LK1 + FF to access the Memory Block.
3
Press the corresponding CO/PBX line key to change data option.
Note: Use the following to enter data:
Sto access the next page.
Tto access the previous page.
Each time a CO/PBX line key is pressed, the LED toggles between On
and Off.
Default Values
Tables 00~15 Used
4
PressNto write the data and advance to the next class. Repeat steps 3 and 4 until last class is assigned.
5
PressNto write the last data.
6
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
Refer to Section 6 Code Restriction in this chapter.
6 6 : N O R M A L D I A L | 1
T I M E D I S P L A Y
D
a
t
a
No.
S
e
tti
ng
Data
Title
CO/PBX
Line LED
Off On
Data Restricted Not restricted
There is no
default setting.

Table of Contents