464 ā Chapter 1 DRAFT 3 Automated Attendant DID Assignment, 4-58
December 2004 NEC Business Solutions Ltd
Doc. No.: 8194 - Release 2.0
December 2004
4-58
System Mode
4
Submode
ā
Data No.
58
PC Programming
+ AU
Automated Attendant DID
Assignment
General Description
Use this Memory Block to determine the action after a DID call arrives at an extension or CAR,
and is not answered after predetermined time.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
NON AA1 AA2 AA3
LK 5 LK 6 LK 7 LK 8
AA4 AA5 AA6 AA7
Page 2
LK 9 LK 10 LK 11 LK 12
AA8
LK 13 LK 14 LK 15 LK 16
Programming Procedures
1
Go off-line.
2
Press LK4 + EHto access the Memory Block.
3
Press corresponding CO/PBX line key to change setting data 1.
Note: Use the following to enter data:
J to move the cursor left
L to move the cursor right
R to move to the next Tel Port No
For example, to assign AA6, press LK7 to display.
Default Values
NON
4
PressNto write the data and display the next line key.
5
Repeat example and step 4 until all line key assignments are complete, and press Nto enter last data.
6
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-4-02 Automated Attendant Transfer Delayed Ringing Time Selection
0 1 / 5 8 : D I D N O N / 1
T I M E D I S P L A Y
Data
No.
Tel Port
No.
(01~99)
A0~C0
Page
No.
Setting
Data
Title