EasyManua.ls Logo

NEC Xen IPK - Tie Line Answer Detect Time Selection

NEC Xen IPK
638 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-17, Tie Line Answer Detect Time Selection DRAFT 3 Chapter 1 – 353
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
3-17
System Mode
3
Submode
Data No.
17
PC Programming
+ ALM
Tie Line Answer Detect Time
Selection
General Description
Use this Memory Block to specify the duration between the time when the receiving Xen system
answers (off-hook) and the time when it is recognised as an answer.
Display
Settings
(Page 1)
LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
0 ms. 130 ms. 260 ms.
390 ms.
LK 5 LK 6 LK 7 LK 8
520 ms. 650 ms. 780 ms. 910 ms.
(Page 2)
LK 1LK 2LK 3LK 4
1040 ms. 1170 ms. 1300 ms. 1430 ms.
LK 5 LK 6 LK 7 LK 8
1560 ms. 1690 ms. 1820 ms. 1950 ms.
Programming Procedures
1
Go off-line.
2
Press LK3 + N + AG to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
Note: The following are used when entering data:
S to go to the next page
T to go to the previous page
R to go to the next CO/PBX Line No.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
N
Answering a call may not be possible if the CO answer detect time is too long.
0 1 / 1 7 : P R E 3 9 0 | 1
T I M E D I S P L A Y
CO/PBX
No.
(01~64)
Data
No.
Title
Setting
Data
Page
No.

Table of Contents

Related product manuals