316 – Chapter 1 DRAFT 3 Centralised Day/Night Switching for Remote Office Assignment, 1-15-13
December 2004 NEC Business Solutions Ltd
Doc. No.: 8194 - Release 2.0
December 2004
1-15-13
System Mode
1
Submode
15
Data No.
13
PC Programming
+ AW
Centralised Day/Night
Switching for Remote Office
Assignment
General Description
Use this Memory Block to assign the Xen IPK to switch Day/Night mode when it receives
the command from a main office
.
Applicable for IPK R2000 and above.
Display
Settings
LK1 LK2 LK3 LK4 LK5 LK6 LK7 LK8
The shaded area indicates
the default setting.
NO
(Deny)
YS
(Allow)
Programming Procedures
1
Go off-line.
2
Press LK1 + LK15 + AC to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the Setting Data option.
4
PressNto write the data, and display the next Memory Block.
5
Program the next Memory Block or p
ressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
7-1 Card Interface Slot Assignment
7-3-01 MIF (LCR) Assignment
7-3-02 MIF (SMDR) Assignment
1-15-00 K-CCIS Main/Remote Office Selection
1-15-02 Common Signal Channel Assignment
1-15-03 Originating Point Code Assignment
1-15-04 Destination Point Code Assignment
1-15-05 Destination Point Code Transfer Assignment
1-15-06 Originating Office Code Number Assignment
1-15-07 K-CCIS Message Response Timeout Assignment
1-15-08 Link Reconnect Allow/Deny Selection
1 3 : C E N D / N N O
T I M E D I S P L A Y
Data
No.
Title
Setting
Data