EasyManua.ls Logo

NEC Xen IPK - Polarity Reverse Selection

NEC Xen IPK
638 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
402 – Chapter 1 DRAFT 3 Polarity Reverse Selection, 3-90
December 2004 NEC Business Solutions Ltd
Doc. No.: 8194 - Release 2.0
December 2004
3-90
System Mode
3
Submode
—
Data No.
90
PC Programming
+ AN
Polarity Reverse Selection
General Description
In some cases a Central Office may provide a line reversed to provide a disconnect signal.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
No
Yes
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1
Go off-line.
2
Press LK3 + N + IK to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
Note: Use the following to enter data:
J to move the cursor left
L to move the cursor right
R to go to the next CO/PBX Line No.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
N
BRI and PRI lines are to be set to YES at all times.
1 1 / 9 0 : R V R S ( Y S )
T I M E D I S P L A Y
CO/PBX
No.
(01~64)
Data
No.
Setting Data
(20 digits maximum)

Table of Contents