1-12-00, ACD/UCD Group Pilot Number Assignment DRAFT 3 Chapter 1 – 271
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
1-12-00
System Mode
1
Submode
12
Data No.
00
PC Programming
+ AA
ACD/UCD Group Pilot
Number Assignment
General Description
Use this Memory Block to specify the Pilot Number of an Automatic Call Distribution/Uniform Call
Distribution (ACD/UCD) Group where incoming calls are terminated.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK12 + KKto access the Memory Block.
3
Enter data using the dial pad.
Note: Use the following to enter data:
J to move the cursor left
L to move the cursor right
K~I to enter numeric data
Settings:
Pilot No. (00~99)
2-digit (00~99)
3-digit (000~999)
4-digit (0000~9999)
Default Values
Not Specified
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-46 Access Code (1-Digit) Assignment
1-1-47 Access Code (2-Digit) Assignment
1-1-48 Access Code (3-Digit) Assignment
1-2-03 2-, 3-, or 4-Digit Station Number Selection
1-8-25 ACD/UCD Group Agent Assignment
1-12-01 ACD/UCD Group Overflow Destination Assignment
0 1 / 0 0 : P I L O T = 0 0