182 – Chapter 1 DRAFT 3 Automated Attendant Message Access Code (2-Digit) Assignment, 1-4-15
December 2004 NEC Business Solutions Ltd
Doc. No.: 8194 - Release 2.0
December 2004
1-4-15
System Mode
1
Submode
4
Data No.
15
PC Programming
+ AU
Automated Attendant Message
Access Code (2-Digit)
Assignment
General Description
Use this Memory Block to enter a 2-digit code to route an incoming call from the Automated
Attendant.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK4 + AE to access the Memory Block.
3
Use the dial pad to enter data.
Note: The following are used when entering data:
K~H to enter Automated Attendant message number
KK~II to enter dial number
Default Values
4
Enter Setting Data. PressNto write the data and to advance the Dial Number.
5
After all data is entered, pressNto write the data.
6
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
Refer to Chapter 2, Guide to Feature Programming.
N
To use default 52~54, ringing must be assigned in Memory Blocks 4-01 [CO/PBX Ring Assignment (Day Mode)] or 4-02
[CO/PBX Ring Assignment (Night Mode)] .
1 5 : A A A C 1 = 0 0 = 0 3 0
T I M E D I S P L A Y
Data
No.
Title
Setting
Data
A.A. Msg.
No.
1~8
Dial
No.
Dial No. Funct. Code Contents
00 ~ 50 030 Specified Station Cal (0)
51 011
Bypass Automated
Attendant
52 015 Paging Zone A Call
53 016 Paging Zone B Call
54 017 Paging Zone C Call
55 ~ 87 000 Not Used
88 020 DSS 1 Call
89 021 DSS 2 Call
90~99 000 Not Used