Xen IPK Programming Manual
Section 5, Function Timer Chart DRAFT 3 Chapter 1 – 521
Doc. No.: 8194 - Release 2.0
December 2004
SECTION 5
FUNCTION TIMER
CHART
The chart on the following pages provides a list of timers that can be
programmed in the system. The information is listed numerically by Memory
Block number. A brief definition and the timing value is given for each timer.
Table 1-3: Function Timer Chart
Timer
Memory
Block
Definition
Timing Value
Minimum Default Maximum
Pause Time
Selection
1-1-00
Duration when no signal is being
sent to a CO/PBX line.
1 sec. 3 sec. 3 sec.
DP Interdigit Time
Selection
1-1-01
Minimum interval between dialling
signals in Dial Pulse dialling.
650/500 ms. 800/800 ms. 800/800 ms.
Hookflash Time
Selection
1-1-02
Timing of a CO/PBX hookflash
from the Recall key of a Multiline
Terminal or a Single Line
Telephone to the CO/PBX line.
20 ms. 600 ms. 5000 ms.
(5 sec.)
Hold Recall Timer
Selection
(Non-Exclusive
Hold)
1-1-03
Specify the time before a held
CO/PBX line recalls the station
that put that line on hold.
25 sec. 25 sec. No Limit
Automatic Redial
Time Selection
1-1-04
Defines the redial timing
parameters when automatic redial
is set to a busy CO/PBX number.
30 sec. 60 sec.
Start Timer
Selection
1-1-05
Specify the time for after dialling
and the start of call duration
display and Talk Start Timer.
2 sec. 10 sec. 70 sec.
CO/PBX Incoming
Ringing Alarm Time
Selection
1-1-06
Specify the time from receiving an
incoming CO/PBX call until the
ringing tone changes to a different
ringing tone level if the call is not
answered.
10 sec. No Limit No Limit
Tie Line Delay
Ringing Timer
Selection
1-1-07
Specify the delay interval between
the time a telephone rings
(accessed by a ringing call in the
Tie/DID line) and the time other
telephones start ringing.
10 sec. No Limit No Limit
Station Transfer/
Camp-On Recall
Timer Selection
1-1-12
The time before a ring transferred
call recalls to the station that
transferred the call.
25 sec. 45 sec. No Limit
Trunk Queuing
Timeout Selection
1-1-37
Specify the time queuing for a
CO/PBX line recalls before being
automatically cancelled.
10 sec. 10 sec. 60 sec.
CO/PBX Prepause
Timer Selection
1-1-57
Specify the pause time before
dialled digits are sent over a
CO/PBX line.
None 1 sec. 15 sec.