212 – Chapter 1 DRAFT 3 External Ring Relay Cycle Selection, 1-7-07
December 2004 NEC Business Solutions Ltd
Doc. No.: 8194 - Release 2.0
December 2004
1-7-07
System Mode
1
Submode
7
Data No.
07
PC Programming
+ BP
External Ring Relay Cycle
Selection
General Description
Use this Memory Block to assign one of six distinctive ringing controls/intervals to relay circuits.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
Cycle 1 Cycle 2
Cycle 3 Cycle 4
LK 5 LK 6 LK 7 LK 8
Cycle 5 Cycle 6 Continuous
Programming Procedures
1
Go off-line.
2
Press L1 + LK7 + KG to access the Memory Block.
3
Press corresponding CO/PBX line key to change the data option.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-2-00 Internal Paging Timeout Selection
1-7-02 External Speaker Connection Selection
2-08 ECR Relay to Tenant Assignment
4-71 Time Class Assignment for Telephone Mode (R2000 and above)
0 7 : E X T R I N G 1 = C Y 3
T I M E D I S P L A Y
Data
No.
Title
Setting
Data
Ext Ring
Relay
(1~4)