Loading...
1-3-06, Hookflash End Time Selection DRAFT 3 Chapter 1 – 159
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
1-3-06
System Mode
1
Submode
3
Data No.
06
PC Programming
+ BTI
Hookflash End Time Selection
General Description
Use this Memory Block to specify the maximum hookflash duration from a Single Line Telephone
to receive a second dial tone.
Display
Settings
(Page 1)
LK 1 LK 2 LK 3 LK 4
The shaded area indicates the default setting.
HST = Hookflash Start Time
00
(HST + 0 ms.)
01
(HST + 100 ms.)
02
(HST + 200 ms.)
03
(HST + 300 ms.)
LK 5 LK 6 LK 7 LK 8
04
(HST + 400 ms.)
05
(HST + 500 ms.)
06
(HST + 600 ms.)
07
(HST + 700 ms.).
(Page 2)
LK 1 LK 2 LK 3 LK 4
08
(HST + 800 ms.)
09
(HST + 900 ms.)
10
(HST + 1000
ms.)
11
(HST + 1100
ms.)
LK 5 LK 6 LK 7 LK 8
12
(HST + 1200
ms.)
13
(HST + 1300
ms.)
14
(HST + 1400
ms.)
15
(HST + 1500
ms.)
Programming Procedures
1
Go off-line.
2
Press LK1 + LK3 + KF to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-3-05 Hookflash Start Time Selection
0 6 : F L S H E N D = 0 1 | 1
T I M E D I S P L A Y
Setting
Data
Title
Data
No.
Page
No.

Table of Contents

Related product manuals