1-3-01, Bounce Protect Time Selection DRAFT 3 Chapter 1 – 153
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
1-3-01
System Mode
1
Submode
3
Data No.
01
PC Programming
+ BTI
Bounce Protect Time Selection
General Description
Use this Memory Block to specify the time before a valid hookflash is detected from a Single Line
Telephone or Voice Mail system.
Display
Settings
(Page 1)
LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
0 ms. 100 ms. 200 ms.
300 ms.
LK 5 LK 6 LK 7 LK 8
400 ms. 500 ms. 600 ms. 700 ms.
(Page 2)
LK 1LK 2LK 3LK 4
800 ms. 900 ms. 1000 ms. 1100 ms.
LK 5 LK 6 LK 7 LK 8
1200 ms. 1300 ms. 1400 ms. 1500 ms.
Programming Procedures
1
Go off-line.
2
Press LK1 + LK3 + KA to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-3-05 Hookflash Start Time Selection
N
Bounce Protect Time should be equal to Hookflash Start Time in Memory Block 1-3-05 Hookflash Start Time Selection.