3-42, DIT Assignment DRAFT 3 Chapter 1 – 381
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
3-42
System Mode
3
Submode
Data No.
42
PC Programming
+ BCT
DIT Assignment
General Description
Use this Memory Block to independently assign a Day Mode direct trunk termination to a station.
Display
Programming Procedures
1
Go off-line.
2
Press LK3 +N+ DBto access the Memory Block.
3
Enter data using the dial pad.
Note: Use the following to enter data:
K~I to enter the numeric data
R to go to the next CO/PBX Line No.
Enter the following:
Station No. (2-, 3-, or 4-digits 00~9999)
CO Port No. (01~64)
Default Values
No Assignment
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
3-45 ANA Assignment
N
A trunk can terminate at only one station, but any number of trunks can terminate at the same station.
0 1 / 4 2 : D I T D =
T I M E D I S P L A Y
Data
No.
Setting Data
Station No.
(2-digit: 00~99)
(3-digit: 000~999)
(4-digit: 0000~9999)
(Incoming)
CO/PBX
No.
(01~64)