486 ā Chapter 1 DRAFT 3 OCC Table to Trunk Group Assignment, 5-03
December 2004 NEC Business Solutions Ltd
Doc. No.: 8194 - Release 2.0
December 2004
5-03
System Mode
5
Submode
ā
Data No.
03
PC Programming
+ AC
OCC Table to Trunk Group
Assignment
General Description
Use this Memory Block to assign each of the 16 OCC Tables to each Trunk Group.
Display
Settings
(Page 1)
LK 1 LK 2 LK 3 LK 4
There is no
default setting.
Table 00 Table 01 Table 02 Table 03
LK 5 LK 6 LK 7 LK 8
Table 04 Table 05 Table 06 Table 07
(Page 2)
LK 1 LK 2 LK 3 LK 4
Table 08 Table 09 Table 10 Table 11
LK 5 LK 6 LK 7 LK 8
Table 12 Table 13 Table 14 Table 15
Programming Procedures
1 Go off-line.
2 Press LK5 + N + KC to access the Memory Block.
3
Press the corresponding CO/PBX line key to enter the data. Operation data
includes:
Note: Use the following to enter data:
J to moves the cursor left
L to moves the cursor right
S to go to the next page
T to go to the previous page
R to go to the next Trunk Group No.
Default Values
Use all tables
4 After entering all data for all pages, press
Nto write the data.
5 Press
Pto go back on-line.
Related Programming
Refer to Section 6, Code Restriction in this chapter.
0 1 / 0 3 : O C C = T R K G | 1
T I M E D I S P L A Y
Trunk Group No.
(01~32)
Data
No.
Title
Page
No.
CO/PBX
Line LED
Off
On
Data Disabled
Enabled