1-1-02, Hookflash Time Selection DRAFT 3 Chapter 1 – 33
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
1-1-02
System Mode
1
Submode
1
Data No.
02
PC Programming
+ BCM
Hookflash Time Selection
General Description
Use this Memory Block to specify the loop open time for a hookflash signal sent to the CO or
PBX when the Recall key on a Multiline Terminal is pressed. A Single Line Telephone (SLT)
generates a hookflash to the CO or PBX line when a Single Line Telephone hookflash
is assigned.
Display
Settings
(Page 1) (Page 2)
LK 1 LK 2 LK 3 LK 4 LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
20 ms. 40 ms. 60 ms. 80 ms. 400 ms. 600 ms. 800 ms. 1 sec.
LK 5 LK 6 LK 7 LK 8 LK 5 LK 6 LK 7 LK 8
100 ms. 140 ms. 160 ms. 200 ms. 1.5 sec. 2 sec. 3 sec. 5 sec.
Programming Procedures
1
Go off-line.
2
Press LK1 + LK1 +KBto access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
Note: Use the following to enter data:
S to go to the next page
T to go to the previous page
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-46 Access Code (1-Digit) Assignment
1-1-47 Access Code (2-Digit) Assignment
1-3-02 SLT Hookflash Signal Selection
4-24 SLT Hookflash Assignment
N
1. A 1- or 2-digit Access Code can be assigned in Memory Block 1-1-46 Access Code (1-Digit) Assignment and
Memory Block 1-1-47 Access Code (2-Digit) Assignment, for Single Line Telephones to send a hookflash signal on a
CO/PBX line (default: 6 #).
2. A hookflash from a Single Line Telephone puts an existing call on hold or sends a hookflash signal on the CO/
PBX line.
0 2 : F L S H 1 0 0 m s 1
T I M E D I S P L A Y
D
a
t
a
No.
Title
Setting
Data
Page
No.