414 – Chapter 1 DRAFT 3 Code Restriction Class Assignment (Day Mode), 4-07
December 2004 NEC Business Solutions Ltd
Doc. No.: 8194 - Release 2.0
December 2004
4-07
System Mode
4
Submode
—
Data No.
07
PC Programming
+ AC
Code Restriction Class
Assignment (Day Mode)
General Description
Use this Memory Block to specify, per station, Code Restriction Class in Day Mode.
Display
Programming Procedures
1
Go off-line.
2
Press LK4 + KG to access the Memory Block.
3
Use dial pad to enter data for Restriction Classes 00 ~15.
Note: Use the following to enter data:
J to move the cursor left
L to move the cursor right
K ~ I to enter numeric data
R to move to the next Tel No
Default Values
All Stations Class 00
4
After entering all data, pressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
Refer to Section 6, Code Restriction in this chapter.
N
Telephone ports A0~C0 are ports 100~120.
0 1 / 0 7 : C L S D A Y = 0 0
T I M E D I S P L A Y
Data
No.
Title
Tel Port
No.
(01~99)
A0~C0
Setting
Data
(00~15)

Table of Contents