Loading...
1-9-04, ID Restriction Class Assignment (Night Mode) DRAFT 3 Chapter 1 – 259
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
1-9-04
System Mode
1
Submode
9
Data No.
04
PC Programming
+ BO
ID Restriction Class
Assignment (Night Mode)
General Description
Use this Memory Block to specify the NIGHT mode code restriction classes for each ID number.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK9 +KD to access the Memory Block.
3
Use the dial pad to enter the data.
Setting Data:
Code Restriction Class 00 ~ 15
Note: Use the following to enter data:
J to move the cursor left
L to move the cursor right
K~I to enter numeric data
R to access the next ID buffer number
Q+1, 2, 3 = A, B, or C for Port Number
ID Buffer Number: 01~99 = 01~99
A0~A9 = 100~109
B0~B9 = 110~119
C0 = 120
Default Values
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-19 Line Selection for Automatic Outgoing Calls
1-1-46 DID Digit Length Selection
1-1-47 DID Digit Conversion Assignment
1-1-48 DID Forward Station Number for Busy Station or Undefined Digit
1-5-23 Outgoing Mode Selection
1-9-00 DISA/ID Code Assignment
1-9-02 DISA/ID Password Effect/Invalid Selection
1-9-03 ID Restriction Class Assignment (Day Mode)
1-9-04 ID Restriction Class Assignment (Night Mode)OMU
0 1 / 0 4 : C L S N T = 0 0
T I M E D I S P L A Y
Data
No.
Title
Setting
Data
ID Buffer No.
(01~96)
ID Buffer No. 01~120 = Code
Restriction Class No.00

Table of Contents