EasyManua.ls Logo

NEC Xen IPK - Trunk Internal Receive Pad Selection

NEC Xen IPK
638 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-30, Trunk Internal Receive Pad Selection DRAFT 3 Chapter 1 – 371
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
3-30
System Mode
3
Submode
Data No.
30
PC Programming
+ BCT
Trunk Internal Receive
Pad Selection
General Description
Use this Memory Block to specify a volume level for calls coming to extensions of a local system
from a distant system.
Display
Settings
(Page 1)
LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
2 dB 4 dB 6 dB
8 dB
LK 5 LK 6 LK 7 LK 8
12 dB 16 dB 3 dB -3 dB
(Page 2)
LK 1LK 2LK 3LK 4
0 dB
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1
Go off-line.
2
Press LK3 + N + CK to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
Note: Use the following to enter data:
S to go to the next page
T to go to the previous page
R to go to the next CO/PBX Line No.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
0 1 / 3 0 : P A D I R 8 | 1
T I M E D I S P L A Y
CO/PBX
No.
(01~64)
Data
No.
Title
Setting
Data
Page
No.

Table of Contents

Related product manuals