154 – Chapter 1 DRAFT 3 SLT Hookflash Signal Selection, 1-3-02
December 2004 NEC Business Solutions Ltd
Doc. No.: 8194 - Release 2.0
December 2004
1-3-02
System Mode
1
Submode
3
Data No.
02
PC Programming
+ BTI
SLT Hookflash Signal
Selection
General Description
Use this Memory Block to specify whether a line is held internally, or if behind a PBX, a hookflash
(HF) signal is sent to the line when a Single Line Telephone user performs a hookflash.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
Hold Flash
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1
Go off-line.
2
Press LK1 + LK3 +KBto access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-02 Hookflash Time Selection
4-24 SLT Hookflash Assignment
N
1. If Hold is specified, the CO/PBX line is put on Exclusive Hold.
2. If Hold is selected, the PBX/CTX line can receive the hookflash signal via Access Code 6# (default).
3. If Flash is specified, press the hookswitch to send the hookflash signal to the PBX/CTX line.