266 – Chapter 1 DRAFT 3 Signalling Selection, 1-11-06
December 2004 NEC Business Solutions Ltd
Doc. No.: 8194 - Release 2.0
December 2004
1-11-06
System Mode
1
Submode
11
Data No.
06
PC Programming
+ AD
Signalling Selection
General Description
Use this Memory Block to specify Loop Start (LS) or Ground Start (GS) Trunk Signalling
when using T1
.
Applicable for R2000 and above.
Display
Settings
LK1 LK2 LK3 LK4 LK5 LK6 LK7 LK8
The shaded area indicates
the default setting.
LS GS
Programming Procedures
1
Go off-line.
2
Press LK1 + LK11 + KF to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
PressNto write data and advance to the next Channel No.
5
Program the next Memory Block or pressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-11-07 DTI Trunk Type Assignment
7-1 Card Interface Slot Assignment
N
The DTI-U( ) ETU must be assigned in the system to set this Memory Block.
0 1 / 0 6 : T R N K 0 1 = L S
T I M E D I S P L A Y
Data
No.
Title
Setting
Data
DTI No.
(01~08)