380 – Chapter 1 DRAFT 3 ACD/UCD Delay Announcement Assignment, 3-41
December 2004 NEC Business Solutions Ltd
Doc. No.: 8194 - Release 2.0
December 2004
3-41
System Mode
3
Submode
—
Data No.
41
PC Programming
+ BCT
ACD/UCD Delay
Announcement Assignment
General Description
Use this Memory Block to specify, per CO Port, whether or not ACD/UCD Delay Announcement
is sent to the calling party for Day and/or Night Mode.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
NN YN NY YY
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1
Go off-line.
2
Press LK3 + N + DAto access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
Note: Use the following to enter data:
R to go to the next CO/PPBX Line No.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
Refer to Chapter 2, Guide to Feature Programming.
0 1 / 4 1 : M S G D / N = N N
T I M E D I S P L A Y
CO/PBX
No.
(01~64)
Setting
Data
Title
Data
No.
Setting Data:
Line
Key
LCD
Indication
ACD/UCD Delay
Announcement
1NN No
2YNDay Only
3 NY Night Only
4 YY Day and Night

Table of Contents