368 – Chapter 1 DRAFT 3 Tie Line Reorder Tone Selection, 3-28
December 2004 NEC Business Solutions Ltd
Doc. No.: 8194 - Release 2.0
December 2004
3-28
System Mode
3
Submode
—
Data No.
28
PC Programming
+ ALT
Tie Line Reorder Tone
Selection
General Description
Use this Memory Block to specify whether or not to send a reorder tone to the originating station
when the number of a distant system is used to originate a call over a Tie line.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
Not Sending
Sending
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1
Go off-line.
2
Press LK3 + N + BH to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
Note: Use the following to enter data:
R to go to the next CO/PBX Line No.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
3-14 Tie/DID Line Type Assignment
0 1 / 2 8 : R O T Y S
T I M E D I S P L A Y
Setting
Data
Title
Data
No.
CO/PBX
No.
(01~64)
Xen IPK
System
Originating Side
Reorder
Tone
Sending
8 - 12
12
Distant
System
((
1111