3-29, Trunk Internal Transmit Pad Selection DRAFT 3 Chapter 1 – 369
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
3-29
System Mode
3
Submode
—
Data No.
29
PC Programming
+ BCT
Trunk Internal Transmit Pad
Selection
General Description
This Memory Block specifies a volume level for calls originated from the extensions of a local
system to a distant system.
Display
Settings
(Page 1)
LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
2 dB 4 dB 6 dB
8 dB
LK 5 LK 6 LK 7 LK 8
12 dB 16 dB 3 dB -3 dB
(Page 2)
LK 1LK 2LK 3LK 4
0 dB
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1
Go off-line.
2
Press LK3 + N + BI to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
Note: Use the following to enter data:
S to go to the next page
T to go to the previous page
R to go to the next CO/PBX Line No.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
0 1 / 2 9 : P A D I T 8 | 1
T I M E D I S P L A Y
Page
No.
Setting
Data
Title
Data
No.
CO/PBX
No.
(01~64)