3-64, DIT Night Mode Delay Answer Enable DRAFT 3 Chapter 1 – 395
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
3-64
System Mode
3
Submode
Data No.
64
PC Programming
+ BCT
DIT Night Mode Delay
Answer Enable
General Description
This Memory Block is used to specify whether or not the DIT Delay Answer Timer shall apply to
CO/PBX calls received when the system is in Night Mode.
Display
Settings
LK 1LK 2LK 3LK 4
The shaded area indicates
the default setting.
No Yes
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1
Go off-line.
2
Press LK3 + N + DDto access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
Note: Use the following to enter data:
J to move the cursor left
L to move the cursor right
Rto go to the next CO/PBX Line No.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
3-62 DIT Delay Answer Timer Selection
N
1. The DIT Delay Answer Time specified in MB , 3-62 shall apply for this purpose.
2. If set to YES, incoming CO/PBX calls during Night Mode will ring for the duration specified in MB , 3-62 before
changing to DIT status.
3. If set to NO, incoming CO/PBX calls during Night Mode will immediately change to DIT status regardless of the setting
in MB , 3-52.
4. This setting only applies to those CO/PBX lines assigned with the DIT facility in MB , 3-44 and MB , 3-45.