7-2, Telephone Type Assignment DRAFT 3 Chapter 1 – 507
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
7-2
System Mode
7
Telephone
2
Data No.
PC Programming
+ BS
Telephone Type Assignment
General Description
Use this Memory Block to specify the type of device that is connected to an ESI port.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
Non
Telephone
DSS Con-
sole
SLT
Adapter
LK 5 LK 6 LK 7 LK 8
Digital Voice
Mail
Programming Procedures
1
Go off-line.
2
Press LK7 + LK2 to access the Memory Block.
3
To change data, press the corresponding CO/PBX line key.
Note: Use the following to enter data:
R: Next Tel Port No.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
Refer to Chapter 2, Guide to Feature Programming.
N
1. Only Multiline Terminals can be assigned to ports 01 and 02.
2. A maximum of four Attendant Add-On Consoles can be installed in the system.
3. A maximum of eight SLT(1)-U( ) ADP adaptors can be installed in the system.
4. A maximum of eight Digital Voice Mail ports are available.
5. When assigning SLT adaptors or Digital Voice Mail ports, Memory Block , 4-10 , Station Number Assignment must be
reassigned also.
6. If more than one DSS console is assigned, make sure that the order of assignment is as follows:
DSS1 must always be a lower port than DSS2
DSS2 must be a lower port than DSS 3
DSS3 must be a lower port than DSS 4
0 1 : T E L
T I M E D I S P L A Y
ESI
Port No.
(01~96)
Setting Data