Loading...
1-8-36, COM Port Parity/Stop Bit Setting Assignment DRAFT 3 Chapter 1 – 249
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
1-8-36
System Mode
1
Submode
8
Data No.
36
PC Programming
+ CSS
COM Port Parity/Stop Bit
Setting Assignment
General Description
Use this Memory Block to define the Parity and Stop bit for the individual COM ports.
Display
Settings
LK 1LK 2LK 3LK 4
The shaded area indicates
the default setting.
Non/1 Non/2 Even/1 Odd/1
LK 5LK 6LK 7LK 8
Programming Procedures
1
Go off-line.
2
Press LK1 + LK8 + CF to access the Memory Block.
3
Use the Line keys to select the parity and stop bit setting.
Default Values
COM 1 = Non/1
COM 2 = Non/1
COM 3 = Non/1 (Not Used)
COM 4 = Non/1
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
1-5-13 Printer Connected Selection
N
COM 1 = PC/LCR Programming
COM 2 = Station Message Detail Recording (SMDR)
COM 3 = Automatic Call Distribution
3 6 : P / S 1 = N O N / 1