1-1-05, Start Timer Selection DRAFT 3 Chapter 1 – 37
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
1-1-05
System Mode
1
Submode
1
Data No.
05
PC Programming
+ BM
Start Timer Selection
General Description
Use this Memory Block to specify the time needed after dialling before the system starts the
Elapsed Call Timer, SMDR Start Timer, and Talk Start Timer.
With IPK R2000 and above, this memory block allows flexible entries and has four classes.
For R2000 only.
For R2000 and above.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
10 sec. 20 sec. 30 sec. 40 sec.
LK 5LK 6LK 7LK 8
50 sec. 60 sec. 70 sec. 2 sec.
Programming Procedures
1
Go off-line.
2
Press LK1 + LK1 + KE to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
PressNto write the data.
5
PressPto go back on-line.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK1 +KEto access the Memory Block.
3
Use the dial pad to enter the time required.
Note:
Jto move cursor left.
Lto move cursor right.
Setting Data (Allow): Class 1 to Class 4: 00 to 99 sec
00 = No Limit
Default values:
Class 1 to Class 4 = 60 secs
0 5 : C A L L S T A R T 1 0 s
T I M E D I S P L A Y
Data
No.
Title
Setting
Data
0 5 : S T A R T X = 0 2 s
T I M E D I S P L A Y
Data
No.
Title
Setting
Data
Class