4-90, SLT Data Line Security Assignment DRAFT 3 Chapter 1 – 475
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
4-90
System Mode
4
Submode
Data No.
90
PC Programming
+ BTT
SLT Data Line Security
Assignment
General Description
Use this Memory Block to specify Normal/Data position for Single Line Telephones (SLTs).
Display
Settings
LK 1LK 2LK 3LK 4
The shaded area indicates
the default setting.
SLT Normal SLT Data
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1
Go off-line.
2
Press LK4 +IK to access the Memory Block.
3
Press the corresponding CO/PBX line key to change data option.
Use the following to change option:
R select next Tel Port No.
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
N
1. When connecting SLT/voice mail, assign SLT Normal. When connecting Fax/Modem, assign SLT Data.
2. If Multiline Terminal is assigned for Data Line Security, Tone Override and Call Alert Notification tones are not heard
from the handset; however, the tone is still sent and heard from the speaker when off-hook.
3. Data Line Security denies a station from barging in, even if Barge-In is allowed in Class of Service.
4. If this Memory Block is set to SLT Data, the Voice Override tone is not heard when doing a Voice Over Split.
5. Telephone ports A0~C0 are ports 100~120.
0 1 / 9 0 : S L T N O R M A L
T I M E D I S P L A Y
Data
No.
Tel Port No.
(01~99)
A0~C0
Title
Setting
Data

Table of Contents