1-4-00, Tandem Transfer Automatic Disconnect Timer Selection DRAFT 3 Chapter 1 – 165
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
1-4-00
System Mode
1
Submode
4
Data No.
00
PC Programming
+ AT
Tandem Transfer Automatic
Disconnect Timer Selection
General Description
Use this Memory Block to specify maximum time before the system automatically disconnects a
Trunk-to-Trunk connection.
With IPK R2000 and above, this memory block allows flexible entry.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK4 + KK to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data
option or enter the time required in minutes
Default Values
060 min
4
PressNto write the data.
5
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
Time Class Assignment for Telephone Mode (R2000 and above)
N
This block is used for Direct Inward System Access (DISA), Trunk-to-Trunk Transfer, Call Forward - Off Premise, and Tie
line tandem features.
0 0 : A U T O D I S 0 6 0
T I M E D I S P L A Y
Data
No. Title
Setting
Data

Table of Contents