32 – Chapter 1 DRAFT 3 DP Interdigit Time Selection, 1-1-01
December 2004 NEC Business Solutions Ltd
Doc. No.: 8194 - Release 2.0
December 2004
1-1-01
System Mode
1
Submode
1
Data No.
01
PC Programming
+ BCM
DP Interdigit Time Selection
General Description
The DP Interdigit Time is the minimum pause time interval between Dial Pulse dialling. Use this
Memory Block to Select either Pattern A or Pattern B.
Display
Settings
LK 1 LK 2 LK 3 LK 4
The shaded area indicates
the default setting.
Pattern A
Pattern B
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1
Go off-line.
2
Press LK1 + LK1 +KAto access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
PressNto write the data.
5
PressPto go back on-line.
N
Use this Memory Block when DP Tie lines or DID are assigned in Memory Block 3-92 [Trunk (Installed, DP/DTMF)
Selection] to send Dial Pulse signalling.
0 1 : D P I N T E R B
T I M E D I S P L A Y
Data
No.
Title
Setting
Data
DP Dial
Data
10 pps 20 pps
Pattern A
650 ms. 500 ms.
Pattern B
800 ms. 800 ms.
Dial
Minimum
Pause
Time
Signal
Dial