178 – Chapter 1 DRAFT 3 Automated Attendant Answer Delay Time Assignment, 1-4-13
December 2004 NEC Business Solutions Ltd
Doc. No.: 8194 - Release 2.0
December 2004
1-4-13
System Mode
1
Submode
4
Data No.
13
PC Programming
+ AU
Automated Attendant Answer
Delay Time Assignment
General Description
Use this Memory Block is assign the number of seconds before the Automated Attendant
answers an incoming CO/PBX call.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK4 + ACto access the Memory Block.
3
Use the dial pad to enter data.
Note: Use the following to enter data:
A~H to enter Automated Attendant message number
KK~II to enter number of seconds.
Default Values
All Automated Attendant Messages:
4 sec.
4
PressNto write the data, and advance to the next A.A.No.
5
After the last entry, press Nto write the data.
6
PressPto go back on-line.
Related Programming
M.B. Number Memory Block Name
Refer to Chapter 2, Guide to Feature Programming.
1 3 : A A D L Y 1 = 0 4 s