4-59, APR Hookflash Selection DRAFT 3 Chapter 1 – 465
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
4-59
System Mode
4
Submode
—
Data No.
59
PC Programming
+ BTM
APR Hookflash Selection
General Description
Use this Memory Block to allow/deny Hookflash for an Analogue Port Adapter (APR) on a
Multiline Terminal.
Display
Settings
LK 1LK 2LK 3LK 4
The shaded area indicates
the default setting.
NO YS
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1
Go off-line.
2
Press LK4 + EI to access the Memory Block.
3
Use the following to enter data:
J to move the cursor left
L to move the cursor right
K~I to enter numeric data or Tel Port No.
– OR –
R to go to next assigned Tel Port No.
Q+1 to enter A for Port Numbers 100~109
Q+2 to enter B for Port Numbers 110~119
Q+3 to enter C for Port Number 120
4
Press the corresponding CO/PBX line key to change the setting data option.
5
PressNto write the data and display Memory Block 4-1 for next Tel Port No.
6
Program the next Tel Port No. or pressPTo go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-02 Hookflash Time Selection
1-3-02 SLT Hookflash Signal Selection
4-40 APR Ring Mode Assignment
4-93 DTMF/DP SLT Type Selection
N
Operation of SLT connected to APR is the same as the Single Line Telephone.
0 1 / 5 9 : H K F L S H N O
T I M E D I S P L A Y
Tel Port
No.
(01~CO)
Data
No.
Title
Setting
Data