EasyManua.ls Logo

NEC Xen IPK - APR Hookflash Selection

NEC Xen IPK
638 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-59, APR Hookflash Selection DRAFT 3 Chapter 1 – 465
Xen IPK Programming Manual
Doc. No.: 8194 - Release 2.0
December 2004
4-59
System Mode
4
Submode
Data No.
59
PC Programming
+ BTM
APR Hookflash Selection
General Description
Use this Memory Block to allow/deny Hookflash for an Analogue Port Adapter (APR) on a
Multiline Terminal.
Display
Settings
LK 1LK 2LK 3LK 4
The shaded area indicates
the default setting.
NO YS
LK 5 LK 6 LK 7 LK 8
Programming Procedures
1
Go off-line.
2
Press LK4 + EI to access the Memory Block.
3
Use the following to enter data:
J to move the cursor left
L to move the cursor right
K~I to enter numeric data or Tel Port No.
OR –
R to go to next assigned Tel Port No.
Q+1 to enter A for Port Numbers 100~109
Q+2 to enter B for Port Numbers 110~119
Q+3 to enter C for Port Number 120
4
Press the corresponding CO/PBX line key to change the setting data option.
5
PressNto write the data and display Memory Block 4-1 for next Tel Port No.
6
Program the next Tel Port No. or pressPTo go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-02 Hookflash Time Selection
1-3-02 SLT Hookflash Signal Selection
4-40 APR Ring Mode Assignment
4-93 DTMF/DP SLT Type Selection
N
Operation of SLT connected to APR is the same as the Single Line Telephone.
0 1 / 5 9 : H K F L S H N O
T I M E D I S P L A Y
Tel Port
No.
(01~CO)
Data
No.
Title
Setting
Data

Table of Contents

Related product manuals